SERVICE PROGRAM MODE
C262/C265 5-20 SM
No. Display No. Menu Function
De-
fault
Setting
30
Master Compression
Time A3/DLT
NOTE: Before this
SP mode, the master
eject box was full at
120 masters.
-
0 - 120
1 - 100
2 - 90
3 - 70
2-6
con’d
31
Master Compression
Time A4
To adjust the maximum
number of masters that can be
put in the master eject box.
This allows the “Full” condition
to occur earlier, so he master
eject box is not heavy when
the user empties it.
NOTE: Requires ACU
(C2625174C) and ECU
(C2622511B) firmware.
-
0 - 160
1 - 130
1
Jam Detection –
Time Length
15 3-30
2
Door Open – Time
Length
15 3-30
3
Continuous Master
Jam Cnt
2 2-10
2-08 CC Call
4
Continuous Paper
Jam Cnt
3 2-10
1
Supply Alarm
OFF On/OFF
2
Master End Alarm
OFF On/OFF
3
Master End Alarm
Count
1 1-2
4
Ink End Alarm
OFF On/OFF
2-09
Supply
Alarm
5
Ink End Alarm
Count
3 1-5
2-10 1
ID 0
Other 15 colors
2
ID 1
Other 15 colors
3
ID 2
Other 15 colors
Color Drum
ID Setting
4
ID 3
Use this SP to assign colors
to the drum ID numbers.
For details, see ‘Drum – Ink
Supply and Kneading – Color
Drum ID Detection’ in
Detailed Section
Descriptions. Also see Note
16.
Other 15 colors
2-12
1
Channel Range
Upper Limit
11 1 to 14
IEEE
802.11b
Setting
2
Channel Range
Lower Limit
1 1 to 14
⇒
Rev. 05/2006