282 Object Trigger Control
The Object Trigger Control tab contains the parameters for opening and closing the
reading gate.
283 OCR
If the OCR parameter is activated, optical character recognition is switched on in the
sensor. The text must be taught in using the OCR Setup wizard.
284 or
The or parameter can be used to select a third signal source/condition for closing the
reading gate.
In order for the reading gate to be closed, one of the signal sources/conditions must
apply.
NOT DEFINED: No function defined for closing the reading gate
READ CYCLE SOURCE: The reading gate is closed by the same signal source that
opened it (e.g., the reading gate opens as soon as an object trips a photoelectric
switch and closes again as soon as the object is clear of the photoelectric switch).
SENSOR / INPUT 1: A signal at digital input 1 (e.g., from a photoelectric switch) causes
the reading gate to close.
SENSOR / INPUT 2: A signal at digital input 2 (e.g., from a photoelectric switch) causes
the reading gate to close.
EXTERNAL INPUT 1: A signal at external digital input 1 (e.g., from a photoelectric
switch) causes the reading gate to close.
EXTERNAL INPUT 2: A signal at external digital input 2 (e.g., from a photoelectric
switch) causes the reading gate to close.
SOPAS COMMAND: A corresponding standard command for closing the reading gate is
expected from a device such as an external control (PLC) (a detailed list of the
commands can be obtained from SICK on request).
TIMER / DISTANCE: The reading gate remains open for a defined time/distance (Read‐
ing gate length).
GOOD READ: The reading gate closes as soon as the GOOD READ condition is met (e.g.,
the required number of codes has been read). This ensures that the reading gate
is only kept open for as long as necessary (direct feedback).
USER-DEFINED COMMAND: For the purpose of closing the reading gate, you can freely
define a corresponding command that is generated by a device such as an exter‐
nal control (PLC) and transmitted to the sensor.
MATCH 1 CONDITION: The reading gate closes as soon as the condition is met.
MULTICODES1 CONDITION: The reading gate closes as soon as the number of detected
codes corresponds to the number specified.
TEACH-IN1 CONDITION: The reading gate closes as soon as the Match-code teach-in 1
condition is met.
TEACH-IN2 CONDITION: The reading gate closes as soon as the Match-code teach-in 2
(Additional) condition is met.
SOPAS PARAMETER OVERVIEW
8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x
97
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK Lector62 Series and is the answer not in the manual?

SICK Lector62 Series Specifications

General IconGeneral
BrandSICK
ModelLector62 Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals