279 Usage PLC-Input Bit1
The Usage PLC-Input Bit1 parameter specifies how the PLC input should be used.
•
NO FUNCTION: The PLC input is not used.
•
DEVICE READY
•
GOOD READ
•
NO READ
•
STATUS OF INPUT SENSOR 1
•
STATUS OF INPUT SENSOR 2
•
STATUS OF EXTERNAL INPUT 1
•
STATUS OF EXTERNAL INPUT 2
The parameter is used in conjunction with the CMF400 operating mode to assign prop‐
erties to PLC inputs. As there is no opportunity to use triggers in the CMF400 communi‐
cation mode, instructions can be issued via the input properties.
280 Usage PLC-Output Bit0
The Usage PLC-Output Bit0 parameter specifies how the PLC output should be used.
•
NO FUNCTION: The PLC output is not used.
•
OBJECT TRIGGER: A digital trigger signal is sent via the PLC output. To use this func‐
tion, you must set the OBJECT TRIGGER CONTROL parameter to the FIELDBUS INPUT value.
The OBJECT TRIGGER CONTROL parameter is located under READING CONFIGURATION ->
OBJECT TRIGGER CONTROL.
•
SET / RESET EXTERNAL OUTPUT 1/2: External output 1 or 2 is reset. To use this function,
you must set the EXTERNAL OUTPUT 1 or EXTERNAL OUTPUT 2 parameter to the FIELDBUS
INPUT value. The EXTERNAL OUTPUT 1/2 parameters can be found under NETWORK / INTER‐
FACES / IOS -> DIGITAL OUTPUTS / BEEPER.
•
DISTANCE CONFIGURATION BIT 0/1: The DYNAMIC FOCUS parameter is controlled via the PLC
output. To use this function, you must set the DYN. CONF. MODE parameter to the
FIELDBUS value.
The parameter is used in conjunction with the CMF400 operating mode to assign prop‐
erties to PLC outputs. As there is no opportunity to use triggers in the CMF400 commu‐
nication mode, instructions can be issued via the output properties.
281 Usage PLC-Output Bit1
The Usage PLC-Output Bit1 parameter specifies how the PLC output should be used.
•
NO FUNCTION: The PLC output is not used.
•
OBJECT TRIGGER: A digital trigger signal is sent via the PLC output. To use this func‐
tion, you must set the OBJECT TRIGGER CONTROL parameter to the FIELDBUS INPUT value.
The OBJECT TRIGGER CONTROL parameter is located under READING CONFIGURATION ->
OBJECT TRIGGER CONTROL.
•
SET / RESET EXTERNAL OUTPUT 1/2: External output 1 or 2 is reset. To use this function,
you must set the EXTERNAL OUTPUT 1 or EXTERNAL OUTPUT 2 parameter to the FIELDBUS
INPUT value. The EXTERNAL OUTPUT 1/2 parameters can be found under NETWORK / INTER‐
FACES / IOS -> DIGITAL OUTPUTS / BEEPER.
•
DISTANCE CONFIGURATION BIT 0/1: The DYNAMIC FOCUS parameter is controlled via the PLC
output. To use this function, you must set the DYN. CONF. MODE parameter to the
FIELDBUS value.
The parameter is used in conjunction with the CMF400 operating mode to assign prop‐
erties to PLC outputs. As there is no opportunity to use triggers in the CMF400 commu‐
nication mode, instructions can be issued via the output properties.