38 Output delay
The Output delay parameter allows you to choose between a configuration based on
length units and a configuration based on time units for the Delay, Label Timeout, Con‐
dition Timeout, and Timeout parameters.
•
DISTANCE-CONTROLLED: The parameter values are entered in mm.
•
TIME-CONTROLLED: The parameter values are entered in ms.
39 Data transmission point
You can use the Data transmission point parameter to define when the reading results
are to be output.
•
END OF READ CYCLE: The reading results of all codes are output as soon as the reading
gate is closed. As a result, the data is output at a definable point in time.
•
AS SOON AS POSSIBLE: The reading results of a code are output as soon as the code
has been identified (even if the reading gate is still open). This means that data
can undergo further processing immediately.
•
NEW CODE: The reading results of a code are output as soon as a code has been
identified. However, before the same code can be output again, another code
must first be identified. As a result, you can prevent a code from being identified
multiple times and the data being output again (e.g., during manual reading).
•
END OF LABEL: The reading results of a code are output as soon as a code leaves the
reading area of the sensor.
In operating mode, image transmission and diagnosis are only available for the END OF
READ CYCLE setting.
40 Output / Result 1
The Output / Result 1 group contains the parameters for adjusting digital output 1.
41 Output / Result 2
The Output / Result 2 group contains the parameters for adjusting digital output 2.