92 Code 128 Family
If the Code 128 Family parameter is activated, decoding is enabled for the activated
Code 128 and EAN 128 code types at the same time. (This requires the Pharmacode
code type to be deactivated.) The configuration tab for the corresponding code types
can be seen and opened in SOPAS ET.
NOTE
As only activated code types are processed, you can increase the processing speed by
deactivating the code types that are not being used.
93 Code 39
If the Code 39 parameter is activated, decoding is enabled for the relevant code type.
NOTE
As only activated code types are processed, the processing speed can be increased by
specifically activating/deactivating the necessary code types.
•
Code name: Code 39 (two-value)
•
Character set: 43 alphanumeric characters (10 digits, 26 letters, 7 special charac‐
ters)
•
Structure: 9 code elements (5 bars, 4 gaps) – 3 wide and 6 narrow
•
Intrinsic safety: Average
•
Spatial requirements: High
•
Standard: ISO/IEC 16388
•
Areas of application: Parcel and postal service
94 Code 93
If the Code 93 parameter is activated, decoding is enabled for the relevant code type.
NOTE
As only activated code types are processed, the processing speed can be increased by
specifically activating/deactivating the necessary code types.
•
Code name: Code 93 (4-value)
•
Character set: 43 alphanumeric characters (10 digits, 26 upper-case letters, 7
special characters: space, -, ., $, /, +, and %)
•
Intrinsic safety: Average
•
Spatial requirements: Low
•
Standard: ISO/IEC 16388
•
Areas of application: Parcel and postal service
SOPAS PARAMETER OVERVIEW
42
O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK
Subject to change without notice