265 Mode
The Mode parameter is used to define whether the CAN interface should be used, and
if so how.
INACTIVE: Communication via the CAN interface is deactivated.
SICK NETWORK: The device is integrated into a SICK network. On a SICK network, only
SICK reading devices are networked via the CAN bus. This type of device group is
used to scan an object from different perspectives and transmit the reading result
to a host. As far as the host is concerned, the device group functions as an individ‐
ual device.
CANOPEN: The device is integrated into an unspecified CAN fieldbus system. The
SICK reading device operates as a slave under a CANopen client (PLC) and can
communicate with devices from other manufacturers.
NOTE
The master/slave or multiplexer/server operating modes are available for the SICK net‐
work. The operating modes are configured on the Network / Interface / IOs tab.
266 Module width
The Module width parameter allows you to choose between an automatic module width
or a user-defined one.
267 Modulo
The Modulo parameter defines the maximum value for the counter.
As soon as this value is reached, the numbering recommences at 1, which results in
existing images being overwritten. In this way, you can restrict the maximum amount of
memory required by the stored images.
268 Mode
The type of parameter switchover can be selected via the Mode parameter:
AUTOMATIC PARAMETER SWITCHOVER (APS): Automatic switchover to an activated APS / EPS
parameter set is carried out after a specified number of attempts, which is config‐
ured in the NUMBER OF ATTEMPTS parameter. One image is captured and decoded by
the sensor per attempt. The activated parameter sets are used one after the other
until the reading operation is successful. The next time a trigger is initiated, the
sensor starts with the parameter set that was last successfully used for reading.
EVENT-BASED PARAMETER SWITCHOVER (EPS): Switchover to an activated parameter set is
carried out based on an external event, which is configured in the EPS SOURCE
parameter.
SOPAS PARAMETER OVERVIEW
8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x
93
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK Lector62 Series and is the answer not in the manual?

SICK Lector62 Series Specifications

General IconGeneral
BrandSICK
ModelLector62 Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals