274 Network / Interface / IOs
Settings for using the CAN bus interface can be made on the Network / Interface / IOs
tab. The CDF600 connection module provides SICK reading devices with a CAN inter‐
face that can be used as follows:
The CAN interface is used to integrate the device into a SICK network. On a SICK
network, only SICK reading devices are networked via the CAN bus. This type of
device group is used to scan an object from different perspectives and transmit
the reading result to a host. As far as the host is concerned, the device group func‐
tions as an individual device. The master/slave or multiplexer/server operating
modes are available for the SICK network. Both operating modes can be com‐
bined.
The reading device can be integrated into an unspecified CAN fieldbus system via
CANopen. The SICK reading device operates as a slave under a CANopen client
(PLC) and can communicate with devices from other manufacturers.
The Network / Interface / IOs folder in the project tree contains all the parameters for
configuring and activating serial interfaces, fieldbus interfaces, digital inputs and out‐
puts, and beepers.
275 Network Options
The Network Options group contains parameters for identifying the reading devices on
the network.
276 Restart interval on sending
If the Restart interval on sending parameter is activated, the time between the heart‐
beat signals starts running again once the reading results have been output.
277 No Reads
The No Reads display field shows how many triggers did NOT result in the Good Read
condition being met.
The triggers involved in setting up the sensor are not included in the statistics.
278 Usage PLC-Input Bit0
The Usage PLC-Input Bit0 parameter specifies how the PLC input should be used.
NO FUNCTION: The PLC input is not used.
DEVICE READY
GOOD READ
NO READ
STATUS OF INPUT SENSOR 1
STATUS OF INPUT SENSOR 2
STATUS OF EXTERNAL INPUT 1
STATUS OF EXTERNAL INPUT 2
The parameter is used in conjunction with the CMF400 operating mode to assign prop‐
erties to PLC inputs. As there is no opportunity to use triggers in the CMF400 communi‐
cation mode, instructions can be issued via the input properties.
SOPAS PARAMETER OVERVIEW
8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x
95
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK Lector62 Series and is the answer not in the manual?

SICK Lector62 Series Specifications

General IconGeneral
BrandSICK
ModelLector62 Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals