Length
If the Inactive parameter is set to the TIMER/TRACKING condition, the Length parameter
can be used to specify how long the digital output should remain activated. The unit
can be selected via the Control system parameter.
165 External Input 1
The number of available digital inputs can be expanded by using the CDB620/CDM420
connection module in conjunction with the CMC600 parameter memory module. The
purpose of the CMC parameter memory module is to act as an input expansion module
and convert a digital signal into a command. External digital inputs generally respond
more slowly than the internal digital inputs of the sensor.
The External Input 1 group contains the parameters for adjusting external digital input
1.
Control system
The Control system parameter allows you to choose between a configuration based on
length units and a configuration based on time units.
DISTANCE-CONTROLLED: The configuration is based on distance increments in mm.
These are either generated by the configuration software (SOPAS)/CAN interface
or via a rotary encoder at the digital input.
TIME-CONTROLLED: The configuration is based on times entered in ms.
Sensitivity
The Sensitivity parameter allows you to choose between edge control and level control.
EDGE: The digital input responds to the switch between Low (0) and High (1)
according to how the Logic parameter is configured. Any signal that is permanently
present is ignored.
LEVEL: The digital input responds to a permanently present signal according to how
the Logic parameter is configured.
Logic
The Logic parameter is used to select the polarity for the Sensitivity parameter.
NOT INVERTED: The digital input responds to a rising edge, i.e., to a switch from Low
(0) to High (1), or to a High signal (1) that is permanently present.
INVERTED: The digital input responds to a falling signal edge, i.e., to a switch from
High (1) to Low (0), or to a Low signal (0) that is permanently present.
Debouncing
Depending on how the Control system parameter is configured, the Debouncing param‐
eter specifies the minimum distance in mm or the minimum time in ms for the signal at
the external input. If the value is not achieved, the signal is not detected.
Depending on the application, this value may have to be adapted in line with the read
cycle rates required.
SOPAS PARAMETER OVERVIEW
8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x
63
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK Lector62 Series and is the answer not in the manual?

SICK Lector62 Series Specifications

General IconGeneral
BrandSICK
ModelLector62 Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals