EasyManuals Logo
Home>SICK>Barcode Reader>Lector62 Series

SICK Lector62 Series User Manual

SICK Lector62 Series
131 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #64 background imageLoading...
Page #64 background image
166 External Input 2
The number of available digital inputs can be expanded by using the CDB620/CDM420
connection module in conjunction with the CMC600 parameter memory module. The
purpose of the CMC parameter memory module is to act as an input expansion module
and convert a digital signal into a command. External digital inputs generally respond
more slowly than the internal digital inputs of the sensor.
The External Input 2 group contains the parameters for adjusting external digital input
2.
Control system
The Control system parameter allows you to choose between a configuration based on
length units and a configuration based on time units.
DISTANCE-CONTROLLED: The configuration is based on distance increments in mm.
These are either generated by the configuration software (SOPAS)/CAN interface
or via a rotary encoder at the digital input.
TIME-CONTROLLED: The configuration is based on times entered in ms.
Sensitivity
The Sensitivity parameter allows you to choose between edge control and level control.
EDGE: The digital input responds to the switch between Low (0) and High (1)
according to how the Logic parameter is configured. Any signal that is permanently
present is ignored.
LEVEL: The digital input responds to a permanently present signal according to how
the Logic parameter is configured.
Logic
The Logic parameter is used to select the polarity for the Sensitivity parameter.
NOT INVERTED: The digital input responds to a rising edge, i.e., to a switch from Low
(0) to High (1), or to a High signal (1) that is permanently present.
INVERTED: The digital input responds to a falling signal edge, i.e., to a switch from
High (1) to Low (0), or to a Low signal (0) that is permanently present.
Debouncing
Depending on how the Control system parameter is configured, the Debouncing param‐
eter specifies the minimum distance in mm or the minimum time in ms for the signal at
the external input. If the value is not achieved, the signal is not detected.
Depending on the application, this value may have to be adapted in line with the read
cycle rates required.
167
FC1-Value on First Position
The FC1-Value on First Position parameter can be used to define an alternative charac‐
ter for the FC1 character (control character at the start of the code) in the case of the
EAN 128 code format.
Up to three characters can be defined. The values must be entered as decimal num‐
bers.
SOPAS PARAMETER OVERVIEW
64
O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK Lector62 Series and is the answer not in the manual?

SICK Lector62 Series Specifications

General IconGeneral
BrandSICK
ModelLector62 Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals