EasyManuals Logo
Home>SICK>Barcode Reader>Lector62 Series

SICK Lector62 Series User Manual

SICK Lector62 Series
131 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #54 background imageLoading...
Page #54 background image
Multiread
The Multiread parameter is used to define the minimum number of successful read
operations (GOOD READS) required in order for the GOOD READ result to be output.
Defining a minimum number of read operations reduces the likelihood of codes being
misinterpreted if the print quality is poor or the contrast is low. At the same time, it
increases the reading reliability.
137
EAN
The GTIN 8 / EAN 8 and GTIN 13 / EAN 13 code types can be activated or deactivated
under the EAN group.
138 Setup
Pressing the Setup button starts the reading process for testing the configuration. Dur‐
ing this process, images are captured in free-running mode and displayed in the main
view.
Changes to the configuration (e.g., image settings or code configuration) or the position
of the sensor (e.g., reading distance or angle) are immediately visible in the main view.
This makes it possible to complete test readings, as well as to check and optimize the
current position and configuration of the sensor.
So that the current contrast setting can be evaluated, the identified codes are dis‐
played in different colors:
Green (excellent): Contrast between 55% and 100%
Yellow (good): Contrast between 20% and 55%
Red (poor): Contrast less than 20%
Behavior of the sensor during editing:
Images are integrated into the image sequence at a rate of one per second so that
changes can be recorded.
So that the current contrast setting can be evaluated, the identified codes are dis‐
played in different colors.
The code content and other relevant data are displayed in the code info box for all
detected codes so that the reading stability can be assessed.
The reading results are transferred to the AUX interface in the configured output
format.
The reading results are not transferred to the host interface.
External triggers at the digital inputs are ignored.
Trigger distribution on the CAN interface is deactivated.
No digital outputs are set.
139
Emcy Inhibit Time
The Emcy Inhibit Time parameter defines the interval that must elapse between the
repeated transmission of emergency objects in ms.
140 Sensitivity
The Sensitivity parameter allows you to choose between edge control and level control.
EDGE: The digital input responds to the switch between Low (0) and High (1)
according to how the Logic parameter is configured. Any signal that is permanently
present is ignored.
LEVEL: The digital input responds to a permanently present signal according to how
the Logic parameter is configured.
SOPAS PARAMETER OVERVIEW
54
O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK Lector62 Series and is the answer not in the manual?

SICK Lector62 Series Specifications

General IconGeneral
BrandSICK
ModelLector62 Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals