306 Check digit test
The see "Check digit test", page 103 parameter is used to define the calculation
method for checking the plausibility of the code content. During this check, a check
digit is calculated from the code content and compared with the check digit within the
code. The method that you select must be the same as the one used during code crea‐
tion. The read operation is only classed as "good" (GOOD READ) if the calculated check
digit matches the one in the code.
NOTE
Check digits prevent codes from being misinterpreted and increase the reading reliabil‐
ity.
307 Pulse
If the Start by parameter is set to the AUTOCYCLE signal source, the Pulse parameter can
be used to specify how long the reading gate should remain open. The unit can be
selected via the Trigger delay parameter.