159 Ethernet Aux Port
The Ethernet Aux Port group contains the parameters for configuring the Ethernet aux
interface. The Ethernet aux interface is typically used for configuring and analyzing the
sensor.
Output Format
The Output Format parameter is used to select the output format for the interface.
NO OUTPUT: No data is output via this interface.
READING DIAGNOSIS: This interface is used to output a diagnosis string for each read‐
ing gate.
OUTPUT FORMAT 1: Data that is output via this interface is formatted in line with the
configuration in the Output Format 1 group.
OUTPUT FORMAT 2: Data that is output via this interface is formatted in line with the
configuration in the Output Format 2 group.
For the reading diagnosis, the following information is combined in a diagnosis string
for each reading gate:
TT: Reading gate duration in ms
OTL: Trigger length in mm
CC: No. of codes per reading gate
FC: Focal position in mm
Code content
Code type
For 1D Symbologies
CL: Code length
RSD1DV: Ratio of scans to decoded scans (reading reliability) in %
For 2D Symbologies
SZ: Symbol size
RES: Cell resolution in pixels
CTV: Symbol contrast in %
UECV: Decodability (unused error correction) in %
MC: Number of multireads per code
Server / Client
The Server / Client parameter is permanently set to the CLIENT value and cannot be
changed.
IP port
The IP-Port parameter can be used to adjust the port number for the Ethernet aux inter‐
face (default value: 2111) in line with the connected PC or control (PLC).
160 Ethernet Host
If the Ethernet Host parameter is activated, the results from the Ethernet host interface
are written to the save destination.
161 Ethernet Host Port
The Ethernet Host Port group contains the parameters for configuring the Ethernet host
interface. The Ethernet host interface is typically used for communication with the con‐
trol.
SOPAS PARAMETER OVERVIEW
58
O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK Lector62 Series and is the answer not in the manual?

SICK Lector62 Series Specifications

General IconGeneral
BrandSICK
ModelLector62 Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals