or
The or parameter can be used to select a second condition for deactivating the digital
output.
In order for the digital output to be deactivated, one of the conditions must be met.
•
---: No second condition selected
•
MATCH 1 CONDITION: The output is deactivated if the code that has been read corre‐
sponds to the MATCH 1 CONDITION match code.
•
MULTICODES1 CONDITION: The output is deactivated if the number of codes that have
been read corresponds to the number specified by the MULTICODES1 CONDITION.
•
TEACH-IN1 CONDITION: The output is deactivated if the code that has been read corre‐
sponds to the TEACH-IN1 CONDITION match code.
•
TEACH-IN2 CONDITION: The output is deactivated if the code that has been read corre‐
sponds to the TEACH-IN2 CONDITION match code.
Logic
The Logic parameter is used to select the polarity of the digital output.
•
NOT INVERTED: If this option is activated, the digital output switches from Low (0) to
High (1).
•
INVERTED: If this option is activated, the digital output switches from High (1) to Low
(0).
Control system
The Control system parameter allows you to choose between a configuration based on
length units and a configuration based on time units.
•
DISTANCE-CONTROLLED: The values for the Länge parameter are entered in mm.
•
TIME-CONTROLLED: The values for the Länge parameter are entered in ms.
Length
If the Inactive parameter is set to the TIMER/TRACKING condition, the Length parameter
can be used to specify how long the digital output should remain activated. The unit
can be selected via the Control system parameter.
44 Evaluation Conditions
Conditions that are checked by the device at each reading gate are defined in the Eval‐
uation Conditions group. If defined conditions are fulfilled, specific actions can be per‐
formed by the device – for example, setting an output signal, ending a reading gate, or
outputting an image or a particular data string.
Evaluation conditions can be used to define situations that serve as reference points in
the device software for flexible process control and data processing. The use of evalua‐
tion conditions shifts the complexity of control tasks from the external controls (PLCs)
into the code reader, meaning costs are reduced.
SOPAS PARAMETER OVERVIEW
8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x
27