Active
The Active parameter is used to select the event that activates the digital output.
•
SOPAS COMMAND: The output can be activated via a command. This allows defined
statuses to be displayed by a connected indicator lamp when a corresponding
command is issued by the control (PLC).
•
DEVICE READY: The output is activated as soon as the sensor is ready for use.
•
GOOD READ: The output is activated if the read operation was successful.
•
NO READ: The output is activated if the read operation was unsuccessful.
•
TEACH-IN 1 OK: The output is activated if the MATCH CODE TEACH-IN 1 has been success‐
fully taught in.
•
TEACH-IN 1 NOK: The output is activated if the MATCH CODE TEACH-IN 1 could not be suc‐
cessfully taught in.
•
TEACH-IN 2 OK: The output is activated if the MATCH CODE TEACH-IN 2 has been success‐
fully taught in.
•
TEACH-IN 2 NOK: The output is activated if the MATCH CODE TEACH-IN 2 could not be suc‐
cessfully taught in.
•
MATCH 1 CONDITION: The output is activated if the code that has been read corre‐
sponds to the MATCH 1 CONDITION match code.
•
MULTICODES1 CONDITION: The output is activated if the number of codes that have
been read corresponds to the number specified by the MULTICODES1 CONDITION.
•
TEACH-IN1 CONDITION: The output is activated if the code that has been read corre‐
sponds to the TEACH-IN1 CONDITION match code.
•
TEACH-IN2 CONDITION: The output is activated if the code that has been read corre‐
sponds to the TEACH-IN2 CONDITION match code.
Inactive
The Inactive parameter is used to select the event that leads to the digital output being
deactivated.
•
TIMER/TRACKING: The output is deactivated on expiry of a specific period (see
"Length", page 84).
•
NEXT OBJECT TRIGGER: The output is deactivated as soon as the next reading gate
opens.
•
SOPAS COMMAND: The output can be deactivated via a command. This allows defined
statuses to be displayed by a connected indicator lamp when a corresponding
command is issued by the control (PLC).
•
GOOD READ: The output is deactivated if the read operation was successful.
•
NO READ: The output is deactivated if the read operation was unsuccessful.
•
TEACH-IN 1START: The output is deactivated as soon as the MATCH CODE TEACH-IN 1 teach-
in process commences.
•
TEACH-IN 2START: The output is deactivated as soon as the MATCH CODE TEACH-IN 2 teach-
in process commences.
•
MATCH 1 CONDITION: The output is deactivated if the code that has been read corre‐
sponds to the MATCH 1 CONDITION match code.
•
MULTICODES1 CONDITION: The output is deactivated if the number of codes that have
been read corresponds to the number specified by the MULTICODES1 CONDITION.
•
TEACH-IN1 CONDITION: The output is deactivated if the code that has been read corre‐
sponds to the TEACH-IN1 CONDITION match code.
•
TEACH-IN2 CONDITION: The output is deactivated if the code that has been read corre‐
sponds to the TEACH-IN2 CONDITION match code.
SOPAS PARAMETER OVERVIEW
26