218 Internal memory (temporary)
If the Internal memory (temporary) parameter is activated, the captured images are
stored in the sensor's internal memory. The stored images are deleted when the sensor
is switched off.
The amount of internal memory available is 15 MB. This is enough to store approxi‐
mately 40 images. The stored images can be transferred to the PC and deleted man‐
ually.
Counter
The Counter parameter is used to define the numbering for the stored images.
•
CYCLIC NO.: The stored images are numbered consecutively up to a definable value
(Modulo). As soon as this value is reached, the numbering recommences at 1,
which results in existing images being overwritten. Likewise, when the device is
restarted or the configuration is changed, the numbering starts again from 1.
Cyclic numbering stores the images that were captured last.
•
TRIGGER NO.: The stored images are numbered consecutively. The number is
increased by 1 as soon as the reading gate opens. When the device is restarted,
the numbering starts again from 1. Once the memory is full, no more images can
be stored. Trigger-based numbering stores the images that were captured first.
219 Interval
The minimum and maximum code length can be defined via the Interval parameter.
Codes are only read if their length falls between these two values.
By defining a minimum and maximum code length, you can restrict the range of codes
to be read. This can lead to a reduction in the decoding time.
220 IP-Address
The Ethernet address for the sensor is set manually via the IP-Address parameter.
Before this can happen, a connection must be established with the sensor at the SERV‐
ICE EMPLOYEE user level.
NOTE
The IP-Address and Subnet mask parameters can be changed via the connection wiz‐
ard if the AUTHORIZED CUSTOMER user level is accessed.
The Ethernet address must match the setting for the Subnet mask parameter and be
adjusted in line with the network.
221
IP port
The IP port parameter can be used to adjust the port number for the Ethernet host
interface (default value: 2112) in line with the connected PC or control (PLC).
SOPAS PARAMETER OVERVIEW