294 PDF 417
If the PDF 417 parameter is activated, decoding is activated for the corresponding code
type. The configuration tab for the corresponding code type can be seen and opened in
SOPAS ET.
NOTE
As only activated code types are processed, you can increase the processing speed by
deactivating the code types that are not being used.
•
Code name: PDF 417
•
Character set: 2,710 numeric, 1,850 alphanumeric, 1,400 ASCII, or 1,108 ISO
characters
•
Symbol size: 3 to 90
•
Intrinsic safety: Very high (error correction)
•
Spatial requirements: Very low
•
Standard: ISO/IEC 15438
•
Areas of application: Parcel and postal service
295 Increase Performance
The parameters in the Increase Performance group can be used to ensure the readabil‐
ity of the codes at higher object speeds and/or to reduce the decoding time.
296 Pharmacode
If the Pharmacode parameter is activated, decoding is activated for the corresponding
code type. The configuration tab for the corresponding code type can be seen and
opened in SOPAS ET.
NOTE
All other code types are deactivated.
•
Code name: Pharmacode (binary)
•
Character set: Numeric characters (integers between 3 and 131,070)
•
Structure: Wide bars: 1, narrow bars: 0 (main code and additional code can be dif‐
ferent colors)
•
Intrinsic safety: High
•
Spatial requirements: Low
•
Standard: Laetus bar code standard
•
Areas of application: Packaging checks in the pharmaceutical industry (must
match a reference code in a code list)
SOPAS PARAMETER OVERVIEW
100
O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK
Subject to change without notice