262 Minimum cell size
The smallest cell structure for decoding a code is defined in mm via the Minimum cell
size parameter.
To optimize the decoding process, the value should be matched as precisely as possi‐
ble to the smallest code element (cell size) that actually exists within the code. The cell
size should be between 60% and 105% of the ideal cell size.
The very smallest cell size must be specified so that codes with varying cell sizes can
still be read reliably.
263
Minimum
The Minimum parameter defines the minimum number of different codes that must be
detected in order for a reading to be classed as "good" (GOOD READ). If the specified
value is not reached, the reading is deemed invalid (NO READ).
In this context, the system counts all the codes that differ from other codes in terms of
the code type, code length, code content, or code position.
264 with number
The with number parameter is used to specify the number for the customer-specific
output format.
SOPAS PARAMETER OVERVIEW
92
O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK Lector62 Series and is the answer not in the manual?

SICK Lector62 Series Specifications

General IconGeneral
BrandSICK
ModelLector62 Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals