Output Format
The Output Format parameter is used to select the output format for the interface.
NO OUTPUT: No data is output via this interface.
OUTPUT FORMAT 1: Data that is output via this interface is formatted in line with the
configuration in the Output Format 1 group.
OUTPUT FORMAT 2: Data that is output via this interface is formatted in line with the
configuration in the Output Format 2 group.
162
Event Monitor
Input signals and output signals are represented graphically in the Event Monitor group.
The signal visualization function allows you to test events such as output triggering or
switching and to check the logic and function of signal sequences.
163 External Output 1
The number of available digital outputs can be expanded by using the CDB620/
CDM420 connection module in conjunction with the CMC600 parameter memory mod‐
ule. The purpose of the CMC parameter memory module is to act as an output expan‐
sion module and convert a digital signal into a command. External digital outputs gen‐
erally respond more slowly than the internal digital outputs of the sensor.
The External Output 1 group contains the parameters for adjusting external digital out‐
put 1.
ACTIVE
The Active parameter is used to select the event that activates the digital output.
SOPAS COMMAND: The output can be activated via a command. This allows defined
statuses to be displayed by a connected indicator lamp when a corresponding
command is issued by the control (PLC).
DEVICE READY: The output is activated as soon as the sensor is ready for use.
GOOD READ: The output is activated if the read operation was successful.
NO READ: The output is activated if the read operation was unsuccessful.
TEACH-IN 1 OK: The output is activated if the MATCH CODE TEACH-IN 1 has been success‐
fully taught in.
TEACH-IN 1 NOK: The output is activated if the MATCH CODE TEACH-IN 1 could not be suc‐
cessfully taught in.
TEACH-IN 2 OK: The output is activated if the MATCH CODE TEACH-IN 2 has been success‐
fully taught in.
TEACH-IN 2 NOK: The output is activated if the MATCH CODE TEACH-IN 2 could not be suc‐
cessfully taught in.
MATCH 1 CONDITION: The output is activated if the code that has been read corre‐
sponds to the MATCH 1 CONDITION match code.
MULTICODES1 CONDITION: The output is activated if the number of codes that have
been read corresponds to the number specified by the MULTICODES1 CONDITION.
TEACH-IN1 CONDITION: The output is activated if the code that has been read corre‐
sponds to the TEACH-IN1 CONDITION match code.
TEACH-IN2 CONDITION: The output is activated if the code that has been read corre‐
sponds to the TEACH-IN2 CONDITION match code.
SOPAS PARAMETER OVERVIEW
8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x
59
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK Lector62 Series and is the answer not in the manual?

SICK Lector62 Series Specifications

General IconGeneral
BrandSICK
ModelLector62 Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals