If the Save Images parameter is activated, the images recorded by the sensor are
stored on a separate image server.
74 Image filter
The Image filter group contains parameters for optimizing the camera image in the
case of noise or special code markings.
75 Set frame rate manually
If the Set frame rate manually parameter is activated, the frame rate (image frequency)
can be specified by the user. If this parameter is deactivated, the reading device oper‐
ates at the maximum frame rate. The REQUEST button can be used to retrieve the current
frame rate of a connected device. There may be a discrepancy between the frame rate
set and the actual frame rate used by the reading device. The device adjusts the frame
rate in line with other settings, such as the shutter time. A long shutter time reduces
the frame rate significantly.
It makes sense to reduce the frame rate for slow applications where the object contain‐
ing the code moves past the reading device slowly. Reducing the frame rate increases
the time for evaluating individual images. This results in increased reading reliability for
each individual image. A lower frame rate is not suitable for fast applications, as you
run the risk of not detecting the code on any image.
76 Image file name
The Image file name parameter can be used to specify the name for the image files.
The image files also contain a consecutive number and, if the Good Read / No Read file
prefix parameter is activated, a name prefix is included as well (GOOD READ or NO READ).
Assigning appropriate file names makes it possible to identify the image files clearly
(e.g., by attributing them to a particular project/device).
77 Image quality
The Image quality parameter can be used to adjust the file size/quality (resolution) of
the stored image files. This setting does not affect the reading speed of the sensor.
An xml file containing the Code info box data is stored for each image.
Quality level 6 (maximum resolution): File size for full image region of interest 354
KB
Quality level 5: File size for full image region of interest 90 KB
Quality level 4: File size for full image region of interest 41 KB
Quality level 3: File size for full image region of interest 24 KB
Quality level 2: File size for full image region of interest 16 KB
Quality level 1: File size for full image region of interest 12 KB
SOPAS PARAMETER OVERVIEW
36
O N L I N E H E L P | Lector62x 8013778/YPV6/2016-01-14 | SICK
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK Lector62 Series and is the answer not in the manual?

SICK Lector62 Series Specifications

General IconGeneral
BrandSICK
ModelLector62 Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals