Heartbeat interval
The Heartbeat interval parameter is used to define the time between the heartbeat sig‐
nals in seconds.
Restart interval on sending
If the Restart interval on sending parameter is activated, the time between the heart‐
beat signals starts again after the reading results have been output.
329 Service Information
Service and maintenance data is displayed in the Service Information group. Mainte‐
nance times can be entered.
•
LAST USER: User name of the last user to be logged in
•
LAST CONFIGURATION AT: Date and time of the last configuration saved in the device
•
LAST MAINTENANCE: Date on which maintenance was last completed
•
NEXT MAINTENANCE: Date on which maintenance should next be completed
330 SICK Visualization Platform
The SVP data output can be activated on the SICK Visualization Platform tab.
The SVP (SICK Visualization Platform) is a dynamic database used to monitor, analyze,
and evaluate all the information, including camera images and videos that are captured
using automatic SICK data collection systems.
331 Scripts
All active scripts in a sensor can be displayed using the Scripts parameter.
332 Script List
All active scripts in a sensor are displayed in the Script List group.
333 Slave Address
The Slave Address parameter displays the slave address of the Profibus node via which
the reading device is connected to the Profibus network. The slave address is set via
the rotary switch on the CDF600.
334 SOPAS (PC)
If the SOPAS (PC) parameter is activated, the captured images are stored on the con‐
nected PC.
For this to happen, the SOPAS configuration software must be running while the images
are being captured. The captured images are shown in the main view of the Online
Image tab.
335 Save permanent
If the Save permanent parameter is activated, the taught-in match code remains stored
in the memory even after the sensor has been switched off.
The save process may be slowed down by the fact that the information is saved in the
device's internal memory, on the microSD memory card, and/or in the CMC600 param‐
eter memory module.
SOPAS PARAMETER OVERVIEW