EasyManuals Logo
Home>SICK>Barcode Reader>Lector62 Series

SICK Lector62 Series User Manual

SICK Lector62 Series
131 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #81 background imageLoading...
Page #81 background image
222 ISO15415 (Data Matrix)
If the ISO15415 (Data Matrix) parameter is activated, the quality of the codes that are
read is evaluated based on ISO/IEC 15415.
General notes on the standard:
The verification method is used to evaluate the code quality and readability universally
and independently of the production process.
The ISO/IEC 15415 standard primarily only refers to Data Matrix codes that are printed
on labels.
The device configuration, the intensity, and the aperture angle of the illumination
should be implemented in accordance with the standard. The verifiers are calibrated in
such a way that the code classification will always have the same result regardless of
which verification device is used. This standard is therefore suitable for verifying that
2D codes, which need to be read by a wide variety of reading systems at any production
site, are fit for purpose. The evaluation result is output either in levels from A to F or as
a numerical value from 4 to 0.
223 ISO TR29158 / AIM DPM (Data Matrix)
If the ISO TR29158 / AIM DPM (Data Matrix) parameter is activated, the quality of the
codes that are read is evaluated based on ISO TR29158/AIM DPM.
General notes on the standard:
The verification method is used to evaluate the code quality and readability universally
and independently of the production process.
The ISO TR29158 and AIM DPM standards supplement the ISO/IEC 15415 standard
and refer to Data Matrix codes that are printed on labels. The classification is per‐
formed using special verification devices known as verifiers.
DPM AIM takes into account the following evaluation criteria:
Damage to fixed finder patterns
Extension of modulation from ISO/IEC 15415
Determination of the final result (grading)
The device configuration, the intensity, and the aperture angle of the illumination
should be implemented in accordance with the standard. The verifiers are calibrated in
such a way that the code classification will always have the same result regardless of
which verification device is used. This standard is therefore suitable for verifying that
2D codes, which need to be read by a wide variety of reading systems at any production
site, are fit for purpose. The evaluation result is output either in levels from A to F or as
a numerical value from 4 to 0.
224 Calibration
Pressing the Calibration button starts the image brightness calibration for the AIM DPM
code evaluation.
SOPAS PARAMETER OVERVIEW
8013778/YPV6/2016-01-14 | SICK O N L I N E H E L P | Lector62x
81
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK Lector62 Series and is the answer not in the manual?

SICK Lector62 Series Specifications

General IconGeneral
BrandSICK
ModelLector62 Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals