Inactive
The Inactive parameter is used to select the event that leads to the digital output being
deactivated.
•
TIMER/TRACKING: The output is deactivated on expiry of a specific period (Length).
•
NEXT OBJECT TRIGGER: The output is deactivated as soon as the next reading gate
opens.
•
SOPAS COMMAND: The output can be deactivated via a command. This allows defined
statuses to be displayed by a connected indicator lamp when a corresponding
command is issued by the control (PLC).
•
GOOD READ: The output is deactivated if the read operation was successful.
•
NO READ: The output is deactivated if the read operation was unsuccessful.
•
TEACH-IN 1START: The output is deactivated as soon as the MATCH CODE TEACH-IN 1 teach-
in process commences.
•
TEACH-IN 2START: The output is deactivated as soon as the MATCH CODE TEACH-IN 2 teach-
in process commences.
•
MATCH 1 CONDITION: The output is deactivated if the code that has been read corre‐
sponds to the MATCH 1 CONDITION match code.
•
MULTICODES1 CONDITION: The output is deactivated if the number of codes that have
been read corresponds to the number specified by the MULTICODES1 CONDITION.
•
TEACH-IN1 CONDITION: The output is deactivated if the code that has been read corre‐
sponds to the TEACH-IN1 CONDITION match code.
•
TEACH-IN2 CONDITION: The output is deactivated if the code that has been read corre‐
sponds to the TEACH-IN2 CONDITION match code.
or
The or parameter can be used to select a second condition for deactivating the digital
output.
In order for the digital output to be deactivated, one of the conditions must be met.
•
---: No second condition selected
•
MATCH 1 CONDITION: The output is deactivated if the code that has been read corre‐
sponds to the MATCH 1 CONDITION match code.
•
MULTICODES1 CONDITION: The output is deactivated if the number of codes that have
been read corresponds to the number specified by the MULTICODES1 CONDITION.
•
TEACH-IN1 CONDITION: The output is deactivated if the code that has been read corre‐
sponds to the TEACH-IN1 CONDITION match code.
•
TEACH-IN2 CONDITION: The output is deactivated if the code that has been read corre‐
sponds to the TEACH-IN2 CONDITION match code.
Logic
The Logic parameter is used to select the polarity of the digital output.
•
NOT INVERTED: If this option is activated, the digital output switches from Low (0) to
High (1).
•
INVERTED: If this option is activated, the digital output switches from High (1) to Low
(0).
Control system
The Control system parameter allows you to choose between a configuration based on
length units and a configuration based on time units.
•
DISTANCE-CONTROLLED: The values for the Length parameter are entered in mm.
•
TIME-CONTROLLED: The values for the Length parameter are entered in ms.
SOPAS PARAMETER OVERVIEW
60