Detailed description
2.12 Block descriptions
Basic logic functions: PLC Basic program powerline (P3 pl)
192 Function Manual, 11/2006, 6FC5397-0BP10-2BA0
Signal Type Type Value range Remark
OldToolMag I INT -1, 0.. Current magazine number of new tool
-1: Tool remains at its location OldToolLoc =
any value.
Only permissible if TaskIdent = 2
OldToolLoc I INT Max. location
number
Current location number of tool to be replaced
Status I INT 1...7, 103...105 Status information about transfer operation
Ready A BOOL 1= transfer completed
Error A INT 0..65535 Error checkback
0: No error has occurred
1: Unknown "TaskIdent"
2: Unknown "TaskIdentNo"
3: Illegal task
("signal "Interface (SS) active" of selected
revolver = "FALSE")
Other values:
The number corresponds to the error message
of the tool management function in the NCK
caused by this transfer.
Pulse diagram
5HDG\
6WDUW
(UURU !








(1) Activation of function by means of a positive edge
(2) Positive acknowledgment: Tool management has been transferred
(3) Reset function activation after receipt of acknowledgment
(4) Signal change using FC
(5) This signal chart is not permissible. The job must generally be terminated since the new tool
positions must be conveyed to the tool management in the NCK.
(6) Negative acknowledgment: Error has occurred, error code in the output parameter "Error".

Table of Contents

Other manuals for Siemens MCP 398C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens MCP 398C and is the answer not in the manual?

Siemens MCP 398C Specifications

General IconGeneral
BrandSiemens
ModelMCP 398C
CategoryControl Systems
LanguageEnglish

Related product manuals