Detailed description
2.4 Frames
Basic logic functions: Axes, coordinate systems, frames (K2)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
133
Deletion of system frames
The system frames in the data management can be deleted during RESET uisng machine
data:
MD24007 $MC_CHSFRAME_RESET_CLEAR_MASK (deletion of system frames during
RESET)
Bit Significance
0 System frame for actual value setting and scratching is deleted during RESET.
1 System frame for zero offset external is deleted during RESET.
2 Reserved, for TCARR and PAROT see MD20150 $MC_GCODE_RESET_VALUES[ ].
3 Reserved, for TOROT and TOFRAME see MD20150 $MC_GCODE_RESET_VALUES[ ].
4 System frame for workpiece reference points is deleted during RESET.
5 System frame for cycles is deleted during RESET.
6 Reserved, RESET response depends on MD20110 $MC_RESET_MODE_MASK.
7 System frame for $P_ISO1FR is deleted during RESET.
8 System frame for $P_ISO2FR is deleted during RESET.
9 System frame for $P_ISO3FR is deleted during RESET.
10 System frame for $P_ISO4FR is deleted during RESET.
2.4.12.4 Part program start
Frame conditions after part program start
Frame Condition after parts program start
Programmable frame Deleted.
Settable frames Retained, depending on:
MD20112 $MC_START_MODE_MASK
Complete basic frame Retained
System frames Retained
External zero offset Retained
DRF offset Retained

Table of Contents

Other manuals for Siemens MCP 398C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens MCP 398C and is the answer not in the manual?

Siemens MCP 398C Specifications

General IconGeneral
BrandSiemens
ModelMCP 398C
CategoryControl Systems
LanguageEnglish

Related product manuals