Functions
2.2 Constant travel time (channel-specific)
Basic logic functions: Acceleration (B2)
14 Function Manual, 11/2006, 6FC5397-0BP10-2BA0
1:
Characteristic with constant travel time
2: Characteristic without constant travel time
a
max
: Maximum acceleration value
v
max
: Maximum velocity value
t: Time
The effect of the constant travel time can be seen from the figure above:
Time: t
1
End of acceleration phase with sudden acceleration 1 * a
max
Interval: t
1
- t
2
Acceleration 0; constant velocity using the parameterized constant travel time
Time: t
2
Start of braking phase with sudden acceleration 1 * a
max
The times t
0
, t
1
' and t
2
' indicate the characteristic that would have been produced had no
constant travel time been defined.
2.2.2 Activation
2.2.2.1 Parameterization
Function
The constant travel time is parameterized for specific channels using machine data:
MD20500 $MC_CONST_VELO_MIN_TIME
(minimum time with constant velocity)
2.2.3 Programming
Key statement
The function is not programmable.

Table of Contents

Other manuals for Siemens MCP 398C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens MCP 398C and is the answer not in the manual?

Siemens MCP 398C Specifications

General IconGeneral
BrandSiemens
ModelMCP 398C
CategoryControl Systems
LanguageEnglish

Related product manuals