Detailed description
2.3 Type -specific output behavior
Basic logic functions: Auxiliary Function Output to PLC (H2)
34 Function Manual, 11/2006, 6FC5397-0BP10-2BA0
2.3 Type-specific output behavior
Function
The output behavior of the auxiliary function relative to a traverse motion programmed in the
part program block can be defined type-specifically in the following machine data:
• MD22200 $MC_AUXFU_M_SYNC_TYPE (output time M functions)
• MD22210 $MC_AUXFU_S_SYNC_TYPE (output time S functions)
• MD22220 $MC_AUXFU_T_SYNC_TYPE (output time T functions)
• MD22230 $MC_AUXFU_H_SYNC_TYPE (output time H functions)
• MD22240 $MC_AUXFU_F_SYNC_TYPE (output time F functions)
• MD22250 $MC_AUXFU_D_SYNC_TYPE (output time D functions)
• MD22252 $MC_AUXFU_DL_SYNC_TYPE (output time DL functions)
Output behavior
The following output behaviors can be parameterized:
MD $MC_AUXFU_xx_SYNC_TYPE = <value>
Value Meaning
0 Output prior to motion
1 Output during motion
2 Output at block end
3 No output to the PLC
4 Output according to the predefined output specification
For a description of the various output behaviors, see Section "Parameter: Output
Behaviors" of the predefined auxiliary functions.
Note
For the output behaviors that can be set for each type of auxiliary function, please refer to
the relevant detailed machine data description.
References:
/AMD/ Exhaustive Description of Machine Data