Detailed description
2.6 Interface structure
Basic logic functions: PLC basic program solution line (P3 sl)
38 Function Manual, 11/2006, 6FC5397-0BP10-2BA0
2.6.2 Interface PLC/HMI
General
The following groups of functions are required for the PLC/HMI interface:
Control signals
Machine operation
PLC messages
PLC status display
Control signals
Some control signals are signal inputs, for example, via the machine control panel, which
have to be taken into account by the HMI. This group of signals includes, for example,
display actual values in MCS or WCS, key disable, etc. These are exchanged with the HMI
via a separate interface data block (DB19).
Machine operation
All operator inputs, which lead to response actions on the machine, are monitored by the
PLC. Operator actions are usually performed on the machine control panel (MCP). However,
it is also possible to perform some operator actions on the HMI e.g. mode selection.
The PLC operating system enters the operating signals sent by the HMI directly into the
interface data blocks. As standard, the basic program routes these operating signals in such
a way that, provided equivalent operator actions are available, these can be performed either
on the HMI or on the MCP. If required, the user can switch off the operation via HMI
through a parameter "MMCToIF" of FB1.

Table of Contents

Other manuals for Siemens MCP 398C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens MCP 398C and is the answer not in the manual?

Siemens MCP 398C Specifications

General IconGeneral
BrandSiemens
ModelMCP 398C
CategoryControl Systems
LanguageEnglish

Related product manuals