Detailed Description
2.6 Spindle monitoring
Basic logic functions: Spindles (S1)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
89
2.6.4 Minimum/maximum Speed of gear step
Minimum speed
The minimum gear step speed is entered in machine data:
MD35140 $MA_GEAR_STEP_MIN_VELO_LIMIT
.
This setpoint speed cannot be undershot by programming an S value, which is too small.
NC/PLC IS:
DB31, ... DBX83.2 (Setpoint speed increased) (Programmed speed too low) is set.
The minimum gear step speed is effective only in speed mode and can only be undershot
by:
Spindle override 0%
M5
S0
NC/PLC IS DB31, ... DBX4.3 )Spindle stop)
Withdraw NC/PLC IS:
DB31, ... DBX2.1 (Controller enable).
NC/PLC IS DB21, ... DBX7.7 (Reset)
NC/PLC IS DB31, ... DBX2.2 (Delete distance-to-go/Spindle reset)
NC/PLC IS DB31, ... DBX18.5 (Oscillation speed)
NC/PLC IS DB21, ... DBX7.4 (NC STOP axes plus spindles)
NC/PLC IS DB31, ... DBX1.3 (Axis/Spindle disable)
NC/PLC IS DB31, ... DBX16.7 (Delete S value)
Maximum speed
The maximum gear step speed is entered in machine data:
MD35130 $MA_GEAR_STEP_MAX_VELO_LIMIT
.
When the gear step is engaged, this setpoint speed cannot be exceeded.
When the programmed spindle speed is limited, NC/PLC IS:
DB31, ... DBX83.1 (Setpoint speed limited) (programmed speed too high)
is set.

Table of Contents

Other manuals for Siemens MCP 398C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens MCP 398C and is the answer not in the manual?

Siemens MCP 398C Specifications

General IconGeneral
BrandSiemens
ModelMCP 398C
CategoryControl Systems
LanguageEnglish

Related product manuals