Basic logic functions: Auxiliary Function Output to PLC (H2)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
55
Supplementary conditions
3
3.1 General constraints
Spindle replacement
Because the auxiliary functions are parameterized channel-specifically, if function: "spindle
replacement" is used, the spindle-specific auxiliary function must be parameterized
immediately in all channels that use the spindles.
Tool management
If tool management is active, the following constraints apply:
T and M<k> functions are not output to the PLC.
Note
k is the parameterized value of the auxiliary function for the tool change (default: 6):
MD22560 $MC_TOOL_CHANGE_M_CODE (auxiliary function for tool change)
If no address extension is programmed, the auxiliary function refers to the master spindle
or the master tool holder of the channel.
Definition of the master spindle:
MD20090 $MC_SPIND_DEF_MASTER_SPIND
Part program instruction: SETMS
Definition of the master tool holder
MD20124 $MC_TOOL_MANAGEMENT_TOOLHOLDER
Part program instruction: SETMTH
Maximum number of auxiliary functions per part program block
A maximum of 10 auxiliary functions may be programmed in one part program block.
DL (additive tool offset)
The following restrictions apply to the DL function:
Only one DL function can be programmed per part program block.
If DL functions are used in synchronous actions, parameter: "Value" is not output to the
PLC.

Table of Contents

Other manuals for Siemens MCP 398C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens MCP 398C and is the answer not in the manual?

Siemens MCP 398C Specifications

General IconGeneral
BrandSiemens
ModelMCP 398C
CategoryControl Systems
LanguageEnglish

Related product manuals