Detailed description
2.12 Block descriptions
Basic logic functions: PLC Basic program powerline (P3 pl)
262 Function Manual, 11/2006, 6FC5397-0BP10-2BA0
2.12.28.3 Checkback signals from user interface for controlling displays
Operating modes and machine functions
Destination:
MCP - Output
Source:
Interface DB (parameter ModeGroupNo)
representation for mode group 1
AUTOMATIC DB11, ... DBX7.0
MDA DB11, ... DBX6.1
JOG DB11, ... DBX6.2
REPOS DB11, ... DBX7.1
REF DB11, ... DBX7.2
TEACH IN DB11, ... DBX7.0
WCS/MCS - output is operated through key actuation.
Call example
CALL FC 26 (
//Machine control panel of the HPU/HT6
//signals to interface
BAGNo := B#16#1, //Mode group no. 1
ChanNo := B#16#1); //Channel no. 1
With these parameter settings, the signals from the first parameterized machine control
panel are sent to the 1st mode group, the 1st channel and all axes.