Detailed description
2.3 Coordinate systems
Basic logic functions: Axes, coordinate systems, frames (K2)
44 Function Manual, 11/2006, 6FC5397-0BP10-2BA0
2.3.4 Additive offsets
Zero offsets external
The "zero offset external" is an axial offset. Unlike with frames, no components for rotation,
scaling and mirroring are possible.
;
=
<
;
<
=
%DVLFFRRUGLQDWHV\VWHP%&6
%DVLF]HURV\VWHP%=6
=HURBRIIVHWBH[
WHUQDO
Figure 2-17 Zero offset external between BCS and BZS
Setting the offset values
The offset values are set:
PLC
By describing system variables
Via the operator panel
From menu "Current zero offsets"
NC Program
By assigning to system variable $AA_ETRANS[axis]
Activation of the offset values
The 0/1 edge of the following PLC signal activates the previously defined offset values:
DB31, ... DBX3.0 (accept external zero offset)
The 0/1 edge change is only evaluated in Automatic operating mode.