Detailed description
2.5 Referencing with distancecoded reference marks
Basic logic functions: Reference Point Approach (R1)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
29
2.5.3 Chronological sequence
Chronological sequence
Referencing with distance-coded reference marks can be divided into two phases:
Phase 1: Travel across the reference marks with synchronization
Phase 2: Traveling to a fixed destination point
'%'%;GHFHOHUDWLRQRIUHIHUHQFHSRLQWDSSURDFK
'%'%;0RWLRQFRPPDQGPLQXV
'%'%;DQGWUDYHUVLQJNH\SOXVPLQXV
'%'%;UHIHUHQFHGV\QFKURQL]HG
9HORFLW\
5HIHUHQFHSRLQWFUHHSYHORFLW\
5HIHUHQFHSRLQWSRVLWLRQLQJYHORFLW\
3KDVH3KDVH
5HIHUHQFHPDUNVOLQHDUPHDVXULQJV\VWHP
W
0'0$B5()3B9(/2B326
0'0$B5()3B9(/2B6($5&+B0$5.(5
Figure 2-12 Distancecoded reference marks