EasyManuals Logo

Siemens MCP 398C Function Manual

Siemens MCP 398C
2184 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #87 background imageLoading...
Page #87 background image
Detailed description
2.1 Axis monitoring
Basic logic functions: Axis monitoring, protection zones (A3)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
21
2.1.3 Speed-setpoint monitoring
Function
The speed setpoint comprises:
Speed setpoint of the position controller
Speed setpoint portion of the feedforward control (with active feedforward control only)
Dift compensation (only for drives with analog setpoint interface)
.9
)HHGIRUZDUGFRQWUROYDOXH
'ULIWYDOXH
DSSOLHVRQO\WRDQDORJGULYHV
7RVSHHG
FRQWUROOHU
6SHHG
VHWSRLQW
PRQLWRULQJ
3RVLWLRQFRQWUROOHU
)ROORZLQJ
HUURU

Figure 2-5 Speed setpoint calculation
The speed-setpoint monitoring ensures by limiting the control or output signal (10V for
analog setpoint interface or rated speed for digital drives) that the physical limitations of the
drives are not exceeded:
MD36210 $MA_CTRLOUT_LIMIT (Maximum speed setpoint)

(J

6SHHGVHWSRLQW>@
0'0$B&75/287B/,0,7>Q@
0'0$B&75/287B/,0,7>Q@
IRUWHVWPRGH
Figure 2-6 Speed setpoint limitation

Table of Contents

Other manuals for Siemens MCP 398C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens MCP 398C and is the answer not in the manual?

Siemens MCP 398C Specifications

General IconGeneral
BrandSiemens
ModelMCP 398C
CategoryControl Systems
LanguageEnglish

Related product manuals