Data lists
5.1 Machine data
Basic logic functions: Various NC/PLC interface signals and functions (A2)
50 Function Manual, 11/2006, 6FC5397-0BP10-2BA0
5.1.3 NC-specific machine data
Number Identifier: $MN_ Description
10350 FASTIO_DIG_NUM_INPUTS Number of active digital NCK input bytes
10360 FASTIO_DIG_NUM_OUTPUTS Number of active digital NCK output bytes
10361 FASTIO_DIG_SHORT_CIRCUIT Short-circuit digital inputs and outputs
11120 LUD_EXTENDED_SCOPE Activate programglobal variables (PUD)
11270 DEFAULT_VALUES_MEM_MSK Activ.
Function: Save DEFAULT values of GUD.
18150 MM_GUD_VALUES_MEM Reserve memory space for GUD
5.1.4 Channelspecific machine data
Number Identifier: $MC_ Description
21015 INVOLUTE_RADIUS_DELTA NC start disable without reference point
21016 INVOLUTE_AUTO_ANGLE_LIMIT Automatic angle limitation for involute interpolation
27800 TECHNOLOGY_MODE Technology in channel
28150 MM_NUM_VDIVAR_ELEMENTS Number of write elements for PLC variables
28530 MM_PATH_VELO_SEGMENTS Number of storage elements for limiting path velocity
in block
5.1.5 Axis/spindlespecific machine data
Number Identifier: $MA_ Description
30350 SIMU_AX_VDI_OUTPUT Output of axis signals for simulation axes
33050 LUBRICATION_DIST Lubrication pulse distance
35590 PARAMSET_CHANGE_ENABLE Parameter set definition possible from PLC
36060 STANDSTILL_VELO_TOL Maximum velocity/speed when axis/spindle stationary
36610 AX_EMERGENCY_STOP_TIME Length of the braking ramp for error states
36620 SERVO_DISABLE_DELAY_TIME Cutout delay servo enable