Detailed description
2.4 Referencing with incremental measurement systems
Basic logic functions: Reference Point Approach (R1)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
21
2.4.4 Phase 3: Traversing to the reference point
Phase 3: Graphic representation
'%'%;UHIHUHQFHSRLQWDSSURDFKGHFHOHUDWLRQ
'%'%;0RWLRQFRPPDQGSOXV
'%'%;0RWLRQFRPPDQGPLQXV
'%'%;DQGWUDYHUVLQJNH\SOXVPLQXV
'%'%;DQGUHIHUHQFHGV\QFKURQL]HG
=HURPDUNSRVLWLRQPHDVXULQJV\VWHP
9HORFLW\
5()(5(1&(32,17$3352$&+9(/2&,7<
5()(5(1&(32,17&5((39(/2&,7<
5()(5(1&(32,17326,7,219(/2&,7<
3KDVH
W
0'0$B5()3B9(/2B6($5&+B0$5.(5
0'0$B5()3B9(/2B326
0'0$B5()3B9(/2B6($5&+B&$0
Figure 2-8 Phase 3: Traversing to the reference point
Phase 3: Start
At the end of phase 2 the machine axis travels at reference point creep velocity. Therefore,
as soon as phase 2 is completed successfully without an alarm, phase 3 is started without
interruption.
Initial situation
The encoder zero mark has been detected.

Table of Contents

Other manuals for Siemens MCP 398C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens MCP 398C and is the answer not in the manual?

Siemens MCP 398C Specifications

General IconGeneral
BrandSiemens
ModelMCP 398C
CategoryControl Systems
LanguageEnglish

Related product manuals