Basic logic functions: Various NC/PLC interface signals and functions (A2)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
45
Examples
4
Parameter set changeover
A parameter-set changeover is performed to change the position-control gain (servo gain
factor) for machine axis X1 from v = 4.0 to Kv = 0.5.
Prerequisites
The parameter set changeover must be enabled by the machine data:
MD35590 $MA_PARAMSET_CHANGE_ENABLE [AX1] = 1 or 2 (parameter set change
possible)
The 1st parameter set for machine axis X1 is set, in accordance with machine data with
index "0" NC/PLC interface:
DB31, … DBX9.0 - DBX9.2 = 0 (controller parameter set)
Parameter-set-dependent machine data
Parameter-set-dependent machine data are set as follows:
Machine data Remarks
MD32200 $MA_POSCTRL_GAIN [0, AX1] = 4.0 Servo gain setting for parameter set 1
MD32200 $MA_POSCTRL_GAIN [1, AX1] = 2.0 Servo gain setting for parameter set 2
MD32200 $MA_POSCTRL_GAIN [2, AX1] = 1.0 Servo gain setting for parameter set 3
MD32200 $MA_POSCTRL_GAIN [3, AX1] = 0.5 Servo gain setting for parameter set 4
MD32200 $MA_POSCTRL_GAIN [4, AX1] = 0.25 Servo gain setting for parameter set 5
MD32200 $MA_POSCTRL_GAIN [5, AX1] = 0.125 Servo gain setting for parameter set 6
MD31050 $MA_DRIVE_AX_RATIO_DENOM [0, AX1] = 3 Denominator load gearbox for parameter set 1
MD31050 $MA_DRIVE_AX_RATIO_DENOM [1, AX1] = 3 Denominator load gearbox for parameter set 2
MD31050 $MA_DRIVE_AX_RATIO_DENOM [2, AX1] = 3 Denominator load gearbox for parameter set 3
MD31050 $MA_DRIVE_AX_RATIO_DENOM [3, AX1] = 3 Denominator load gearbox for parameter set 4
MD31050 $MA_DRIVE_AX_RATIO_DENOM [4, AX1] = 3 Denominator load gearbox for parameter set 5
MD31050 $MA_DRIVE_AX_RATIO_DENOM [5, AX1] = 3 Denominator load gearbox for parameter set 6
MD31060 $MA_DRIVE_AX_RATIO_NUMERA [0, AX1] = 5 Counter load gearbox for parameter set 1
MD31060 $MA_DRIVE_AX_RATIO_NUMERA [1, AX1] = 5 Counter load gearbox for parameter set 2
MD31060 $MA_DRIVE_AX_RATIO_NUMERA [2, AX1] = 5 Counter load gearbox for parameter set 3
MD31060 $MA_DRIVE_AX_RATIO_NUMERA [3, AX1] = 5 Counter load gearbox for parameter set 4
MD31060 $MA_DRIVE_AX_RATIO_NUMERA [4, AX1] = 5 Counter load gearbox for parameter set 5
MD31060 $MA_DRIVE_AX_RATIO_NUMERA [5, AX1] = 5 Counter load gearbox for parameter set 6

Table of Contents

Other manuals for Siemens MCP 398C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens MCP 398C and is the answer not in the manual?

Siemens MCP 398C Specifications

General IconGeneral
BrandSiemens
ModelMCP 398C
CategoryControl Systems
LanguageEnglish

Related product manuals