Detailed Description
2.10 Working with tool environments
Basic logic functions: Tool Offset (W1)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
171
2.10.5 Read T, D, DL from a tool environment
GETTENV function
The GETTENV function is used to read the T, D and DL numbers stored in a tool
environment.
The GETTENV function is a predefined subprogram. It must, therefore, be programmed in a
separate block.
Syntax:
Status = GETTENV(_NAME, _TDDL)
Value/parameter:
Status
INT
0: Function OK
-1: No memory reserved for tool environments:
MD18116 $MN_MM_NUM_TOOL_ENV = 0 (number of tool environments in TO
area).
i.e. the "tool environments" functionality is not available.
-2: A tool environment with the name specified in _NAME does not exist.
_NAME
STRING
Name of the tool environment, from which the T, D and DL numbers can be read
_TDDL[3]
INT
This integer array contains:
- in "_TDDL[0]" the T number of the tool,
- in "_TDDL[1]" the D number of the tool,
- in "_TDDL[2]" the DL number of the tool,
whose tool environment in the data set is stored with the name "_NAME".
It is possible to omit the first parameter in the GETTENV function call (e.g., GETTENV(,
_TDDL)) or to pass a null string as the first parameter (e.g., GETTENV("", _TDDL)). In both
of these two special cases, the T, D and DL numbers of the active tool are returned in
_TDDL.

Table of Contents

Other manuals for Siemens MCP 398C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens MCP 398C and is the answer not in the manual?

Siemens MCP 398C Specifications

General IconGeneral
BrandSiemens
ModelMCP 398C
CategoryControl Systems
LanguageEnglish

Related product manuals