EasyManuals Logo

Siemens MCP 398C Function Manual

Siemens MCP 398C
2184 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #395 background imageLoading...
Page #395 background image
Basic logic functions: Velocities, Setpoint/Actual Value Systems, Closed-Loop Control (G2)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
7
Detailed description
2
2.1 Velocities, traversing ranges, accuracies
2.1.1 Velocities
Maximum path and axis velocities and spindle speed
The maximum path and axis velocities and spindle speed are influenced by the machine
design, the dynamic response of the drive and the limit frequency of the actual-value
acquisition (encoder limit frequency).
The maximum axis velocity is defined in machine data:
MD32000 $MA_MAX_AX_VELO (maximum axis velocity).
The maximum permissible spindle speed is defined via machine data:
MD35100 $MA_SPIND_VELO_LIMIT (maximum spindle speed).
For more information, see:
References:
/FB1/ Function Manual, Basic Functions; Spindles (S1)
As well as limiting using MD32000, the control limits the maximum path velocity in relation to
the situation and according to the following formula:
'5,9(B(1&B5$7,2B180(5$>Q@
'5,9(B$;B5$7,2B180(5$>Q@
'5,9(B$;B5$7,2B'(120>Q@
,17B,1&5B3(5B00
/($'6&5(:B3,7&+
'5,9(B(1&B5$7,2B'(120>Q@
,QWHUQDOLQFUHPHQWVPP
(QFRGHULQFUHPHQWVPP
(1&B5(62/>Q@LQWHUQDOPXOWLSOLFDWLRQ

Table of Contents

Other manuals for Siemens MCP 398C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens MCP 398C and is the answer not in the manual?

Siemens MCP 398C Specifications

General IconGeneral
BrandSiemens
ModelMCP 398C
CategoryControl Systems
LanguageEnglish

Related product manuals