EasyManuals Logo

Siemens MCP 398C Function Manual

Siemens MCP 398C
2184 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1519 background imageLoading...
Page #1519 background image
Detailed description
2.12 Block descriptions
Basic logic functions: PLC basic program solution line (P3 sl)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
245
Declaration of the function
FUNCTION FC 26 : VOID
// NAME:
HPU_MCP
VAR_INPUT
BAGNo : BYTE ;
ChanNo: BYTE ;
END_VAR
BEGIN
END_FUNCTION
Description of formal parameters
The table below shows all formal parameters of the "HPU_MCP" function.
Signal Type Type Range of values Remark
BAGNo I BYTE 0 - b#16#0A
and
b#16#10 - b#16#1A
No. of mode group to which the mode signals
are transferred.
BAGNo >= b#16#10 means access to the
second machine control panel.
ChanNo I BYTE 0 - B#16#0A Channel no. for the channel signals
2.12.27.1 MCP selection signals to the user interface
Operating modes and machine functions
Source:
MCP - Key
Destination:
Interface DB (parameter ModeGroupNo)
representation for mode group 1
AUTOMATIC DB11, ... DBX0.0
MDI DB11, ... DBX0.1
JOG DB11, ... DBX0.2
REPOS DB11, ... DBX1.1
REF DB11, ... DBX1.2
TEACH IN DB11, ... DBX1.0
INC 1 ... 10 000, INC Var. DB11, ... DBB2, Bit 0 to 5

Table of Contents

Other manuals for Siemens MCP 398C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens MCP 398C and is the answer not in the manual?

Siemens MCP 398C Specifications

General IconGeneral
BrandSiemens
ModelMCP 398C
CategoryControl Systems
LanguageEnglish

Related product manuals