Basic logic functions: Emergency Stop (N2)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
17
Data lists
5
5.1 Machine data
5.1.1 Drive-specific machine data
Number Identifier: $MD_ Description
1404 PULSE_SUPPRESSION_DELAY Time for pulse suppression
5.1.2 Axis/spindlespecific machine data
Number Identifier: $MA_ Description
36610 AX_EMERGENCY_STOP_TIME Length of the braking ramp for error states
36620 SERVO_DISABLE_DELAY_TIME Cutout delay servo enable
5.2 Signals
5.2.1 Signals to NC
DB number Byte.Bit Description
10 56.1 EMERGENCY STOP
10 56.2 Acknowledge EMERGENCY STOP