EasyManuals Logo

Siemens MCP 398C Function Manual

Siemens MCP 398C
2184 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #118 background imageLoading...
Page #118 background image
Detailed description
2.2 Protection zones
Basic logic functions: Axis monitoring, protection zones (A3)
52 Function Manual, 11/2006, 6FC5397-0BP10-2BA0
Preactivation
Only preactivated protection zones can be activated from the PLC user program.
3
:
;
=
0
3UHDFWLYDWHGSURWHFWLRQ]RQH
Figure 2-13 Example: Turning machine with preactivated protection zone for a sensor.
Deactivation
A protection zone can be deactivated from a part program. Additionally an active,
preactivated protection zone can be set again in the preactivated (= ineffective) state through
the PLC user program.
RESET response
The activation status of a protection zone is retained even after NC-RESET and program
end.
Memory requirements
The memory requirement of the persistent memory is determined with following machine
data :
MD18190 $MN_MM_NUM_PROTECT_AREA_NCK (Number of available machine-defined
protection zones)
MD28200 $MC_MM_NUM_PROTECT_AREA_CHAN (Number of available channel-defined
protection zones)
The memory requirement in the dynamic part with regard to the protection zones is
established with following machine data :
MD28210 $MC_MM_NUM_PROTECT_AREA_ACTIVE (Maximum number of protection
zones that can be activated simultaneously in the channel)
MD28212 $MC_MM_NUM_PROTECT_AREA_CONTUR (Maximum number of definable
contour elements per protection zone)

Table of Contents

Other manuals for Siemens MCP 398C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens MCP 398C and is the answer not in the manual?

Siemens MCP 398C Specifications

General IconGeneral
BrandSiemens
ModelMCP 398C
CategoryControl Systems
LanguageEnglish

Related product manuals