EasyManuals Logo

Siemens MCP 398C Function Manual

Siemens MCP 398C
2184 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #133 background imageLoading...
Page #133 background image
Examples
4.1 Axis monitoring
Basic logic functions: Axis monitoring, protection zones (A3)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
67
N83 $AC_WORKAREA_CS_LIMIT_PLUS[2,Z] = –600
N90 $AC_WORKAREA_CS_PLUS_ENABLE[2,A] = FALSE
N92 $AC_WORKAREA_CS_MINUS_ENABLE[2,A] = FALSE
Activate working area limitation group 2
In order to activate the working area limitation group 2, following instruction must exist in the
part program:
...
N100 WALCS2 ...
...

Table of Contents

Other manuals for Siemens MCP 398C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens MCP 398C and is the answer not in the manual?

Siemens MCP 398C Specifications

General IconGeneral
BrandSiemens
ModelMCP 398C
CategoryControl Systems
LanguageEnglish

Related product manuals