Detailed description
2.12 Block descriptions
Basic logic functions: PLC basic program solution line (P3 sl)
104 Function Manual, 11/2006, 6FC5397-0BP10-2BA0
Signal Type Type Range of values Remark
Op1KeyIn
Op2KeyIn
I POINTER P#Ex.0 or
P#Mx.0 or
P#DBn.DBXx.0.
Start address for the input signals
of the affected direct control key
modules
Op1KeyOut
Op2KeyOut
I POINTER P#Ax.0 or
P#Mx.0 or
P#DBn.DBXx.0.
Start address for the output signals
of the affected direct control key
modules
Op1KeyBusAdr
Op2KeyBusAdr
I INT 1..191 Direct control keys via
Ethernet: TCU Index:
Op1KeyStop
Op2KeyStop
I BOOL 0: Start transfer of
direct control key signals
1: Stop transmission
of direct control key signals
Op1KeyNotSend
Op2KeyNotSend
I BOOL 0: Send and receive operation
activated
1: Receive
direct control key signals only
OpKeyBusType I BYTE b#16#55 b#16#55: Ethernet
IdentMcpBusAdr I INT 1..254 only IE devices
IdentMcpProfilNo I BYTE 0, 1 Profile of a device
0: complete device
1: only direct control keys
IdentMcpBusType I BYTE b#16#5 only IE devices
IdentMcpStrobe I BOOL Activate query
MaxBAG
Q
INT 1..10 Number of mode groups
MaxChan
Q
INT 1..10 Number of channels
MaxAxis
Q
INT 1..31 Number of axes
ActivChan
Q
ARRAY[1...
10] OF
BOOL
Bit string for active channels
ActivAxis
Q
ARRAY[1..
31] OF
BOOL
Bit string for active axes