Detailed description
2.12 Block descriptions
Basic logic functions: PLC basic program solution line (P3 sl)
128 Function Manual, 11/2006, 6FC5397-0BP10-2BA0
PI service: CONFIG
Function Reconfiguration:
The reconfiguration command activates machine data, which have been entered sequentially
by the operator or the PLC, almost in parallel.
The command can only be activated when the control is in RESET state or the program is
interrupted (NC stop at block limit). An FB 4 error checkback message is output if these
conditions are not fulfilled (state = 3).
Parameterization
Signal Type Value range Meaning
PIService ANY PI.CONFIG Reconfiguration
Unit INT 1
WVar1 INT 1 Classification
PI service: DIGION
Function Digitalize On:
Selecting digitizing in the specified channel.
Parameterization
Signal Type Value range Meaning
PIService ANY PI.DIGION Digitizing on
Unit INT 1 to 10 Channel
PI service: DIGIOF
Function Digitalize Off:
Deactivating digitizing in the specified channel.
Parameterization
Signal Type Value range Meaning
PIService ANY PI.DIGIOF Digitizing off
Unit INT 1 to 10 Channel