2.1 Velocities, traversing ranges, accuracies
Basic logic functions: Velocities, Setpoint/Actual Value Systems, Closed-Loop Control (G2)
18 Function Manual, 11/2006, 6FC5397-0BP10-2BA0
Example 2:
In addition to the change in Example 1, the machine data input/output of linear accelerations
must be in ft/s
2
instead of m/s
2
(initial state).
(The internal unit is mm/s
2
.)
0'6&$/,1*B86(5B'()B0$6.
0'6&$/,1*B)$&7256B86(5B'()>Q@
0'6&$/,1*B)$&7256B86(5B'()>@
IW
PP
V
V
PP
V
PP
V
+



ELWQRDQGELWQRIURPH[DPSOH
DVKH[YDOXH
Index 4 defines the "linear acceleration" in the "Scaling factors of physical quantities" list.