Detailed description
2.5 Optimization of the control
Basic logic functions: Velocities, Setpoint/Actual Value Systems, Closed-Loop Control (G2)
70 Function Manual, 11/2006, 6FC5397-0BP10-2BA0
MD32950
The function is activated via the following machine data setting:
MD32950 $MA_POSCTRL_DAMPING = 1.
It is possible to enter both positive and negative values,
which will then serve to scale the injection of the positional deviation.
Standard setting:
MD32950 $MA_POSCTRL_DAMPING = 0.
In this case, the injection of positional deviation is inactive.
Note
The weighting of machine data:
MD32950 $MA_POSCTRL_DAMPING
can be set on the basis of step responses, for example.
If the control approaches the stability limit (vibration inclination increases), then the
parameter is too large.
Supplementary condition
1. The functional expansion is available for all control variants,
which use SIMODRIVE 611 digital drives.
2. The function can only be used on axes with two encoders:
MD30200 $MA_NUM_ENCS = 2
One of the encoders must be parameterized as an indirect measuring system and the
other as a direct measuring system.
If these conditions are not met, reset alarm 26016 will acknowledge the function when an
attempt is made to activate machine data:
MD32950 $MA_POSCTRL_DAMPING.
The function remains deactivated internally when this alarm is active.

Table of Contents

Other manuals for Siemens MCP 398C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens MCP 398C and is the answer not in the manual?

Siemens MCP 398C Specifications

General IconGeneral
BrandSiemens
ModelMCP 398C
CategoryControl Systems
LanguageEnglish

Related product manuals