Brief description
1.2 Overview of auxiliary functions
Basic logic functions: Auxiliary Function Output to PLC (H2)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
9
S functions
S (spindle function)
Address extension Value
Value range Meaning Value range Type Meaning Number
8)
0 - 12 Spindle number
5)
0 - +/-3.4028 ex 38
3)
REAL Spindle speed 3
Remarks:
The master spindle of the channel is addressed if no an address extension is specified.
Application
Spindle speed.
Remarks
S functions are assigned to auxiliary function group 3 by default.
Without an address extension, the S functions refer to the master spindle of the channel.
S-function-specific machine data:
MD22210 $MC_AUXFU_S_SYNC_TYPE (Output time of the S functions)
H functions
H (aux. function)
Address extension Value
Value range Meaning Value range Type Meaning Number
8)
-2147483648 -
+2147483647
INT 0 - 99 Any
0 - +/-3.4028exp38
2) 3) 4)
REAL
Any 3
Remarks:
The functionality must be implemented by the user in the PLC user program.
Application
User-specific auxiliary functions.
Remarks
H-function-specific machine data:
MD22110 $MC_AUXFU_H_TYPE_INT (type of H-auxiliary function is an integer)
MD22230 $MC_AUXFU_H_SYNC_TYPE (Output time of the H functions)

Table of Contents

Other manuals for Siemens MCP 398C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens MCP 398C and is the answer not in the manual?

Siemens MCP 398C Specifications

General IconGeneral
BrandSiemens
ModelMCP 398C
CategoryControl Systems
LanguageEnglish

Related product manuals