Examples
4.1 Defining auxiliary functions
Basic logic functions: Auxiliary Function Output to PLC (H2)
60 Function Manual, 11/2006, 6FC5397-0BP10-2BA0
Requirements
Spindle 1 (master spindle)
Note
Default assignments
The auxiliary functions M3, M4, M5, M70 and M1=3, M1=4, M1=5, M1=70 of spindle 1
(master spindle) are assigned to the second auxiliary function group by default.
All S and S1 values of spindle 1 (master spindle) are assigned to the third auxiliary
function group by default.
The gear stage last programmed is to be output after block search. The following auxiliary
functions are assigned to the ninth auxiliary function group for this reason:
M40, M41, M42, M43, M44, M45
M1=40, M1=41, M1=42, M1=43, M1=44, M1=45
The auxiliary functions M3, M4, M5, M70 and M1=3, M1=4, M1=5, M1=70 (second auxiliary
function group) and S and S1 values (third auxiliary function group) should have the
following output behavior:
Output duration one OB40 cycle (quick acknowledgment)
Output prior to motion
The auxiliary functions for gear changeover M40 to M45 and M1=40 to M1=45 (ninth
auxiliary function group) should have the following output behavior:
Output duration one OB1 cycle (normal acknowledgment)
Output prior to motion
Spindle 2
Only one M function for directional reversal may be programmed in one block. The
direction of rotation last programmed is to be output after block search. The following
auxiliary functions are assigned to the tenth auxiliary function group for this reason:
M2=3
, M2=4, M2=5, M2=70
All S2 values are assigned to auxiliary function group 11.
The auxiliary functions M2=3, M2=4, M2=5, M2=70 (tenth auxiliary function group) and S2
values (auxiliary function group 11) should have the following output behavior:
Output duration one OB40 cycle (quick acknowledgment)
Output prior to motion
Cooling water
It is not permissible to switch the cooling water on and off in one part program block. After
a block search, the cooling water will be switched on or off. For this purpose, the following
auxiliary functions are assigned, for example, to auxiliary function group 12 or 13:
12. auxiliary function group: M50, M51
13. auxiliary function group: M52, M53

Table of Contents

Other manuals for Siemens MCP 398C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens MCP 398C and is the answer not in the manual?

Siemens MCP 398C Specifications

General IconGeneral
BrandSiemens
ModelMCP 398C
CategoryControl Systems
LanguageEnglish

Related product manuals