2.4 Program test
Basic logic functions: Mode group, channel, program operation, reset response (K1)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
33
Display
Active single block mode is indicated by a reversal in the relevant field in the status line on
the operator interface.
As soon as the part program execution has processed a part program block in single-block
mode, interface signal:
DB21, ...DBX35.3 (program status interrupted)
is set.
Control options
For certain sequences, continuous program execution can be desirable despite the selection
of single-block mode.
Machine data:
MD10702 $MN_IGNORE_SINGLEBLOCK_MASK
specifies which operations are to be processed without interruption.
• Internal ASUPs
• User ASUBs
• Intermediate blocks
• Block search group blocks (action blocks)
• Init blocks
• Subroutines with DISPLOF
• Nonreorganizable blocks
• Nonrepositionable blocks
• Reposition block without travel information
• Tool approach block.
Assignments between operations and bits of the machine data can be found in the machine
data description.