EasyManuals Logo

SimCom SIM5300E User Manual

SimCom SIM5300E
267 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #163 background imageLoading...
Page #163 background image
SIM5300E AT Command Manual V1.02
152
If sending is successful:
When +CIPQSEND=0
<n>,SEND OK
When +CIPQSEND=1
DATA ACCEPT:<n>,<length>
If sending fails:
<n>,SEND FAIL
Execution Command
AT+CIPSEND
response">", then
type data for send,
tap CTRL+Z to send, tap ESC to
cancel the operation
Response
This Command is used to send changeable length data.
If single IP connection is established (+CIPMUX=0)
If connection is not established or module is disconnected:
If error is related to ME functionality:
+CME ERROR <err>
If sending is successful:
When +CIPQSEND=0
SEND OK
When +CIPQSEND=1
DATA ACCEPT:<length>
If sending fails:
SEND FAIL
Note:
This Command can only be used in single IP connection mode
(+CIPMUX=0) and to send data on the TCP or UDP connection that has
been established already. Ctrl-Z is used as a termination symbol. ESC is
used to cancel sending data. There are at most <size> bytes which can
be sent at a time.
Parameters
<n> A numeric parameter which indicates the connection number
<size> A numeric parameter which indicates the data length sent at a time
<length> A numeric parameter which indicates the length of sending data,
it must be less than <size>
Reference
Note:
The data length which can be sent depends on network status.
Set the time that send data automatically with the Command of
AT+CIPATS.
SIMCOM CONFIDENTIAL FILE

Table of Contents

Other manuals for SimCom SIM5300E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SimCom SIM5300E and is the answer not in the manual?

SimCom SIM5300E Specifications

General IconGeneral
BrandSimCom
ModelSIM5300E
CategoryControl Unit
LanguageEnglish

Related product manuals